CAT 4500 error 4900M - %C4K_SWITCHINGENGINEMAN-4-VFEICINTERRUPTICCERR:


We have recently upgraded a number of these model switches to cat4500e-ipbasek9-mz.122-54.SG1.bin ... about 12 weeks ago. Of the 6 that we upgraded, one has had the following triggered on it.

Nov 1 13:54:54.049 ACDT: %C4K_SWITCHINGENGINEMAN-4-VFEICINTERRUPTICCERR: VFE IC iccErr interrupt. valid: 1 errStatus: 0x2000000 replyBusParity: 0xBD replyBusLog.rep: 0x8000000 0x180000C7400 log.rep: 0xF8082600000000 0x0 0x0 0x101035A extLog.rep: 0xFF00000000 0x0 0x0 0x0 tcamIfRxErrStatus.rep: 0x2000000 IC CAM stsReg.rep: 0x0 0
Nov 1 14:04:56.113 ACDT: %C4K_SWITCHINGENGINEMAN-4-VFEICINTERRUPTICCERR: VFE IC iccErr interrupt. valid: 1 errStatus: 0x2000000 replyBusParity: 0xBD replyBusLog.rep: 0x8000000 0x180000C7400 log.rep: 0xF8082600000000 0x0 0x0 0x101035A extLog.rep: 0xFF00000000 0x0 0x0 0x0 tcamIfRxErrStatus.rep: 0x2000000 IC CAM stsReg.rep: 0x0 0
Nov 1 14:14:58.173 ACDT: %C4K_SWITCHINGENGINEMAN-4-VFEICINTERRUPTICCERR: VFE IC iccErr interrupt. valid: 1 errStatus: 0x2000000 replyBusParity: 0xBD replyBusLog.rep: 0x8000000 0x180000C7400 log.rep: 0xF8082600000000 0x0 0x0 0x101035A extLog.rep: 0xFF00000000 0x0 0x0 0x0 tcamIfRxErrStatus.rep: 0x2000000 IC CAM stsReg.rep: 0x0 0
Nov 1 14:25:00.237 ACDT: %C4K_SWITCHINGENGINEMAN-4-VFEICINTERRUPTICCERR: VFE IC iccErr interrupt. valid: 1 errStatus: 0x2000000 replyBusParity: 0xBD replyBusLog.rep: 0x8000000 0x180000C7400 log.rep: 0xF8082600000000 0x0 0x0 0x101035A extLog.rep: 0xFF00000000 0x0 0x0 0x0 tcamIfRxErrStatus.rep: 0x2000000 IC CAM stsReg.rep: 0x0 0
Nov 1 14:35:02.305 ACDT: %C4K_SWITCHINGENGINEMAN-4-VFEICINTERRUPTICCERR: VFE IC iccErr interrupt. valid: 1 errStatus: 0x2000000 replyBusParity: 0xBD replyBusLog.rep: 0x8000000 0x180000C7400 log.rep: 0xF8082600000000 0x0 0x0 0x101035A extLog.rep: 0xFF00000000 0x0 0x0 0x0 tcamIfRxErrStatus.rep: 0x2000000 IC CAM stsReg.rep: 0x0 0
Nov 1 14:45:04.373 ACDT: %C4K_SWITCHINGENGINEMAN-4-VFEICINTERRUPTICCERR: VFE IC iccErr interrupt. valid: 1 errStatus: 0x2000000 replyBusParity: 0xBD replyBusLog.rep: 0x8000000 0x180000C7400 log.rep: 0xF8082600000000 0x0 0x0 0x101035A extLog.rep: 0xFF00000000 0x0 0x0 0x0 tcamIfRxErrStatus.rep: 0x2000000 IC CAM stsReg.rep: 0x0 0
Nov 1 14:55:06.417 ACDT: %C4K_SWITCHINGENGINEMAN-4-VFEICINTERRUPTICCERR: VFE IC iccErr interrupt. valid: 1 errStatus: 0x2000000 replyBusParity: 0xBD replyBusLog.rep: 0x8000000 0x180000C7400 log.rep: 0xF8082600000000 0x0 0x0 0x101035A extLog.rep: 0xFF00000000 0x0 0x0 0x0 tcamIfRxErrStatus.rep: 0x2000000 IC CAM stsReg.rep: 0x0 0

What concerns me is that there was nothing in the logs preceding this alarm .. documentation reflects that it's an informative message and no action is required ... but why would it keep repeating on a 10 minute cycle since it was first triggered?

What you have seen are the correctable parity errors. To learn more about Parity Errors please click here for CCO documentations. Please click here for documentation on troubleshooting line cards.

In general that is usually transient if seen once - or HW problem in case of mulitple occurrencies. So if that is still scrolling - please consider the replacement of Supervisor (RMA). The scrolling message is confusing and possibly should be addressed in SW. However the root cause for it is HW parity error. The reload should stop this error - on re-occurrence replace it.

In regards to scrolling message It can be both - DE actually need to look into the code. SO if that parity error stays there as not correctable and switch is doing regular routine and finds that again and again - thus the continious logs. I guess nothing can be changed in the way it handles that.


Citation - This blog post does not reflect original content from the author. Rather it summarizes content that are relevant to the topic from different sources in the web. The sources might include any online discussion boards, forums, websites and others.